Search Your Error Code for Solution

Code
Item
Detection timing
Trouble isolation
C0001
LCT communication error
Due to malfunctioning of the software or other causes, the watchdog timer triggers a reset when time is up
-
C0202
Tray 1 feeder up/down abnormality
The paper feed tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Tray 1
C0204
Tray 2 feeder up/down abnormality
The paper feed tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Tray 2
C0206
Tray3 lift-up failure
The lift-up upper sensor is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Tray 3
C0208
Tray4 lift-up failure
Tray 4
C0209
LCT elevator motor failure
The elevator motor pulse sensor (PS10) cannot detect both edges of H/L even after the set period of time has elapsed while the elevator motor (M5) is turning backward/for- ward (raise/lower).
LCT
C0210
LCT lift failure
The lift-up upper limit sensor (PS4) is not blocked even after the set period of time has elapsed after the paper lift-up operation began.
The lift-up upper limit sensor (PS4) is not blocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-up operation began.
The lift-up lower sensor (PS13) is not unblocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-up operation began.
The lift-up upper limit sensor (PS4) is not blocked even after the set period of time has elapsed after the paper lift-up operating.
The lift-up lower limit sensor (PS13) is not blocked even after the set period of time has elapsed after the paper lift-down operation began.
The lift-up lower limit sensor (PS13) is not blocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-down operation began.
The lift-up upper limit sensor (PS4) is not unblocked even after the set pulse is detected by the elevator motor pulse sensor (PS10) after the paper lift-down operation began.
The lower limit over run sensor (PS7) is blocked while the paper lift-down operating.
LCT
C0211
Manual feed up/down abnormality
Paper does not unblock the manual lift-up position sensor even after the transport motor rotates for a given period of time after the position is switched from stand by posi- tion at lift-up plate to the feed position.
The manual lift-up position sensor is not blocked even after the transport motor rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Manual
C0212
LCT ejection failure
The drawer cannot be determined to be out of position even after the set period of time has elapsed after the tray lock solenoid (SD1) is energized after the lowering opera- tion is finished.
LCT
C0213
LCT shift gate malfunction
The division board position sensor (PS14) cannot be set to L even after the set period of time has elapsed after the operation of the division board position motor (M3) began with the division board position sen- sor (PS14) set to L.
LCT
C0214
LCT shifting failure
The shifter stop position sensor (PS11) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right).
The shifter stop position sensor (PS11) is not blocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the shift operation began (shift to the right).
The shifter home position sensor (PS12) is not unblocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the shift operation began (shift to the right).
The shifter home position sensor (PS12) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left).
The shifter home position sensor (PS12) is not blocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the return operation began (shift to the left).
The shifter stop position sensor (PS11) is not unblocked even after the set pulse is detected by the shift motor pulse sensor (PS8) after the return operation began (shift to the left).
LCT
C0215
LCT shift motor malfunc- tion
The shift motor pulse sensor (PS8) cannot detect both edges of H/L even after the set period of time has elapsed while the shift motor (M4) is turning backward/forward (raise/lower).
LCT
C1004
FNS communication error
When the FS control board (FSCB) is receiving data, a communication error is detected.
-
C1081
SD communication error
When a communication error is detected between the FS control board (FSCB) and the SD control board (SDCB).
Half-Fold/ Tri-Fold/ Center Sta- pling
C1113
Center-staple lead edge stopper motor malfunction

The leading edge stopper home sensor (PS45) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M20) is turned ON.
Staple, Half-Fold/ Tri-Fold Center Stapling
C1114
Center-staple front adjust drive motor malfunction

The center staple alignment home sensor/F (PS42) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/F (M24) is turned ON.
Half-Fold/ Tri-Fold Center Stapling
C1115
Center-staple knife drive motor malfunction

The center fold plate home sensor (PS47) is turned neither ON nor OFF even after the set period of time has elapsed after the cen- ter fold plate motor (M26) is turned ON.
Half-Fold/ Tri-Fold Center Stapling
C1116
Center-staple transfer motor malfunction

The center fold roller motor (M25) does not reach the specified speed even after the set period of time has elapsed after it starts to operate.
Half-Fold/ Tri-Fold Center Stapling
C1150
Center-staple rear adjust drive motor malfunction

The center staple alignment home sensor/R (PS41) is turned neither ON nor OFF even after the set period of time has elapsed after the center staple alignment motor/R (M23) is turned ON.
Half-Fold/ Tri-Fold Center Stapling
C1156
Center-staple paddle roller motor malfunction (trailing edge)

Even after the set period of time has elapsed after the upper paddle motor (M21) starts running, a change of motor lock signal is not detected and neither the paper detec- tion sensor/1 (PS43) nor the paper detec- tion sensor/2 (PS44) is turned ON.
Half-Fold/ Tri-Fold Center Stapling
C1158
Undetectable
C1181
Malfunctioning of belt up/ down movement

The belt position sensor (PS13) is not turned OFF after the set period of time has elapsed after the belt retract solenoid (SD5) is turned ON.
The belt position sensor (PS13) is not turned ON after the set period of time has elapsed after the conveyance motor/1 (M5) is turned ON.
Staple
C1182
Shift motor drive malfunc- tion

The shift home sensor (PS6) is not blocked after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the home position.)
The shift home sensor (PS6) is not unblocked twice in a row after the set period of time has elapsed after the shift motor (M2) is turned ON (start of moving to the shift position.)

When moving to the front (home) position: The tray 2 shift home sensor (PS25) is not turned ON even after the set period of time has elapsed after the tray 2 shift motor (M16) is turned ON.
When moving to the rear (shift) position: The tray 2 shift home sensor (PS25) is not turned OFF even after the set period of time has elapsed after the tray 2 shift motor (M16) is turned ON.
Staple
C1183
Elevate drive malfunction

During downward movement, the tray 2 upper limit sensor (PS24) is turned OFF and the tray 2 lower limit sensor (PS21) is turned ON.
The elevate motor (M15) lock signal remains set to H for a set period of time while the elevate motor (M15) is turning.
The tray2 upper position switch (SW2) is turned ON even after the set period of time has elapsed while the elevate motor (M15) is energized.
The tray2 lower position switch (SW3) is turned ON even after the set period of time has elapsed while the elevate motor (M15) is energized.

When the exit tray is moving up:
When the tray up/down motor (M2) starts rotating with the output of the tray lower limit sensor (PS6) being ON, PS6 is not turned OFF even after the set period of time has elapsed.
The paper surface detect sensor/1 (PS2) or the paper surface detect sensor/2 (PS3) is not turned ON even after the set period of time has elapsed after the tray up/down motor (M2) starts rotating.
When the exit tray is moving down:
The tray lower limit sensor (PS6) is not turned ON even after the set period of time has elapsed after the tray up/down motor (M2) starts rotating.
C1190
Alignment plate motor drive malfunction

• The alignment plate home sensor (PS17) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment plate motor (M13) is turned ON.
-
Alignment plate R drive malfunction

The alignment plate home sensor/R (PS9) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment motor/R (M4) is turned ON.
-
C1191
Alignment plate F drive malfunction

The alignment plate home sensor/F (PS8) is turned neither ON nor OFF even after the set period of time has elapsed after the alignment motor/F (M3) is turned ON.
-
C1194
Leading edge stopper motor drive malfunction

The leading edge stopper home sensor (PS20) is turned neither ON nor OFF even after the set period of time has elapsed after the leading edge stopper motor (M14) is turned ON.

The leading edge stopper home sensor (PS14) is not turned OFF after the set period of time has elapsed after the stapler motor (M8) is turned ON.
Staple
C11A1
Tray 2 exit roller pressure/ retraction malfunction

The exit roller pressure sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the exit roller retraction motor (M9) is turned ON.
Exit roller pressure/ retraction malfunction

The pick up roller position sensor (PS12) is turned neither ON nor OFF even after the set period of time has elapsed after the pick up roller position motor (M1) is turned ON.
C11A2
Accommodation roller pressure/ retraction mal- function

The accommodation roller pressure sensor (PS13) is turned neither ON nor OFF even after the set period of time has elapsed after the accommodation roller retraction motor (M10) is turned ON.
C11A7
Tray 3 exit roller pressure/ retraction malfunction

The tray3 exit roller retraction sensor (PS35) is turned neither ON nor OFF even after the set period of time has elapsed after the tray3 exit roller retraction motor (M17) is turned ON.
C11B0
Stapler movement drive malfunction

During home position search, neither the stapler home sensor/1 (PS18) nor the sta- pler home sensor/2 (PS19) is turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M11) is turned ON.

During the home position search, the stapler home sensor (PS11) is not turned ON or OFF even after the set period of time has elapsed after the stapler movement motor (M7) is turned ON.
Staple
C11B2
Staple drive malfunction

The stapler home sensor is turned neither ON nor OFF even after the set period of time has elapsed after the stapler motor is turned ON.

During the initial operation, the stapler home sensor is not turned ON even after the set period of time has elapsed after the stapler movement motor (M7) is turned ON.
The stapler home sensor is not turned ON after the set period of time has elapsed after the stapler motor (M8) is turned ON.
Staple
C11B5
Saddle stapler drive mal- function

The center stapler home sensor is turned neither ON nor OFF even after the set period of time has elapsed after the center stapler motor is turned ON.
Half-Fold/ Tri-Fold Center Stapling
C11C0
Punch motor drive mal- function

The punch home sensor/1 (PS100) is not turned ON even after the set period of time has elapsed while the punch motor/1 (M100) is energized.
C11E0
Duplex path switching motor drive malfunction

The duplex path switching sensor (PS3) is turned neither ON nor OFF even after the set period of time has elapsed after the duplex path switching motor (M2) is turned ON.
Finisher route change malfunction

The route change home sensor (PS4) is not blocked after the set period of time has elapsed after the route change motor (M3) is turned ON (start of shifting to the lower tray route.)
The route change home sensor (PS4) is not unblocked after the set period of time has elapsed after the route change motor (M3) is turned ON (start of shifting to the upper tray route.)
C11E1
Upper lower path switch- ing motor drive malfunc- tion

The upper lower path switching sensor (PS26) is turned neither ON nor OFF even after the set period of time has elapsed after the upper lower path switching motor (M6) is turned ON.
C11E2
Tray1 path switching motor drive malfunction

The tray1 path switching home sensor (PS7) is turned neither ON nor OFF even after the set period of time has elapsed after the tray1 path switching motor (M8) is turned ON.
C1301
Fan motor drive malfunc- tion

While the motor is rotating, the fan lock sig- nal remains L for the set period of time.
C1402
FS NVRAM memory error

When the main power switch is turned ON, malfunctioning of the non-volatile memory on the FS control board (FSCB) is detected.
C2152
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement.
The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
C2164
PC charge malfunction
When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predeter- mined period of time.
C2253
Color PC motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
C2254
Color PC motor’s turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
C225D
Color developing unit de-engagement failure
Engagement is not completed in a given period time after the color dev. unit engaged motor has started engagement operation.
De-engagement is not completed in a given period time after the color dev. unit engaged motor has started de-engagement opera- tion.
C2355
Transfer belt cleaner cooling fan motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
C2411
Developing unit (C) new article release
The status with the new unit is not cleared after the new developing unit is set.
C2412
Developing unit (M) new article release
C2413
Developing unit (Y) new article release
C2414
Developing unit (K) new article release
C2551
Abnormally low toner density detected cyan TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hop- per.
C2552
Abnormally high toner density detected cyan TCR sensor
TC ratio in the developing unit which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
C2553
Abnormally low toner density detected magenta TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hop- per.
C2554
Abnormally high toner density detected magenta TCR sensor
TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
C2555
Abnormally low toner density detected yellow TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hop- per.
C2556
Abnormally high toner density detected yellow TCR sensor
TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
C2557
Abnormally low toner density detected black TCR sensor
When sampling data is determined in TC ratio calculation control, TCR sensor output is higher than a predetermined value for a predetermined number of times in a row even though there is toner in the sub hop- per.
C2558
Abnormally high toner density detected black TCR sensor
TC ratio in the developing unit, which is determined by toner replenishing amount control mechanism, is a predetermined value or more for a given number of times consecutively.
C2559
Cyan TCR sensor adjustment failure
TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
C255A
Magenta TCR sensor adjustment failure
C255B
Yellow TCR sensor adjustment failure
C255C
Black TCR sensor adjustment failure
C2561
Cyan TCR sensor failure
Alarm signals for a TCR sensor are detected more than the predetermined num- ber of times.
This detection is used for detecting discon- nection of TCR sensor connector.
C2562
Magenta TCR sensor failure
C2563
Yellow TCR sensor failure
C2564
Black TCR sensor failure
C2650
Main backup media access error
Contact the responsible people of KMBT before taking some countermeasures.
C2A11
Drum unit/C new release failure
The status with the new unit is not cleared after the new drum unit is set.
C2A12
Drum unit/M new release failure
C2A13
Drum unit/Y new release failure
C2A14
Drum unit/K new release failure
C3101
Fusing roller separation failure
With the fusing roller being retracted, the pulse of the encoder sensor does not change even after the specified period of time has passed after the fusing pressure roller retraction motor started rotating.
With the fusing roller being pressed, the encoder pulse sensor does not change even after the specified period of time has passed after the fusing pressure roller retraction motor started rotating.
With the pressure roller being pressed, the fusing pressure roller home sensor did not turn ON (pressed) even after the fusing pressure roller retraction sensor counted up the specified number of pulse after the fus- ing pressure roller retraction motor started rotating.
C3201
Fusing motor failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
C3202
Fusing motor turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
C3302
Fusing cooling fan motor/ 2,3 failure to turn
The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
C3421
Fusing heaters trouble (Heating side)
Detected temperature of the heating roller thermistor/C does not go up a given range of temperature even after a lapse of given period of time at warm up.
Detected temperature of the heating roller thermistor/C does not reach to a given tem- perature even after a lapse of given period of time after warm up is completed.
C3423
Fusing heaters trouble (Pressurizing side)
Detected temperature of the pressure roller thermistor does not go up a given range of temperature even after a lapse of given period of time at warm up.
Detected temperature of the pressure roller thermistor does not reach to a given temper- ature even after a lapse of given period of time after warm up is completed.
C3721
Fusing abnormally high temperature detection (Center of the heating side)
Detected temperature of the heating roller thermistor/C goes beyond a given tempera- ture for a given period of time consecutively.
Detected temperature of the heating roller thermistor/M goes beyond a given tempera- ture for a given period of time consecutively.
The hard protector signal error is detected for a given period of time consecutively.
C3722
Fusing abnormally high temperature detection (Edge of the heating side)
Detected temperature of the heating roller thermistor/S goes beyond a given tempera- ture for a given period of time consecutively.
C3723
Fusing abnormally high temperature detection (Pressurizing side)
Detected temperature of the pressure roller thermistor goes beyond a given temperature for a given period of time consecutively.
C3821
Fusing abnormally low temperature detection (Heating side)
Detected temperature of the heating roller thermistor/C goes below a given tempera- ture for a given period of time consecutively after warm up is completed.
Detected temperature of the heating roller thermistor/M goes below a given tempera- ture for a given period of time consecutively after warm up is completed.
C3823
Fusing abnormally low temperature detection (Pressurizing side)
Detected temperature of the pressure roller thermistor goes below a given temperature for a given period of time consecutively after warm up is completed.
C3921
Fusing sensor wire breaks detection
(Heating side)
The maximum value and minimum value of detected temperature of the heating roller thermistor/C, M and S are compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum of either thermistor is below or over a given temperature.
The detected temperature gap between the heating roller thermistor /C and the heating roller thermistor/M surpasses a given tem- perature.
C3923
Fusing sensor wire breaks detection
(Pressurizing side)
The maximum value and minimum value of detected temperature of the pressure roller thermistor are compared after a lapse of given time from starting of warm up and the gap between the value of maximum and minimum is below or over a given tempera- ture.
The pressure heater lights up for a given period of time consecutively.
C4101
Polygon motor rotation trouble
The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor.
Motor lock signal detects HIGH for a given period time consecutively during the poly- gon motor is rotating.
C4501
Laser malfunction
SOS signal is not detected even after the lapse of a given period of time after staring the laser output.
SOS signal is not detected for a given period of time during printing or IDC sensor adjustment.
C5102
Transport motor’s failure to turn
The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
C5103
Transport motor’s
turning at abnormal timing
The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
C5351
Power supply cooling fan motor’s failure to turn
The fan lock signal remains HIGH for a pre- determined continuous period of time while the motor remains stationary.
C5352
Undetectable
C5353
Undetectable
C5354
Exhaust fan motor’s fail- ure to turn
The fan lock signal remains HIGH for a pre- determined continuous period of time while the motor remains stationary.
C5355
Cooling fan motor/3’s failure to turn
The fan lock signal remains HIGH for a pre- determined continuous period of time while the motor remains stationary.
C5357
Undetectable
C5501
AC signal abnormality
Signal is not detected for a given period of interval when AC frequency is measured with the power switch ON or when fusing heater is turned ON/OFF.
C5601
Engine control malfunction
Engine control malfunction is detected with port monitor control.
C6102
Drive system home sensor malfunction
The scanner home sensor is unable to detect the scanner located at its home posi- tion.
The scanner home sensor is unable to detect a scanner even when the scanner motor has been driven to move the scanner over the maximum travelling distance.
The scanner home sensor detects the scan- ner when the scanner has moved the maxi- mum travelling distance from the position, at which it blocks the scanner home sensor.
Scanner
C6103
Slider over running
The scanner home sensor detects the scan- ner at its home position during a period of time that begins with the time when a pre- scan command and a scan preparation command are executed and ends when a home return command is executed.
Scanner
C6301
Undetectable
C6704
Image input time out
Image data is not input from the CCD board (CCDB) to the MFP board (MFPB).
Scanner
C6751
CCD clamp/gain adjustment failure
The adjustment value is 0 or 255 during a CCD clamp adjustment.
The peak value of the output data is 64 or less during a CCD gain adjustment.
Scanner
C6752
ASIC clock input error (front side)
When starting the scanner, verification on reading and writing the predetermined value for image processing ASIC on CCD board was conducted, and verification failure was detected.
C6753
ASIC clock input error (back side)
C6901
DSC board mount failure 1
When MFP detects that DSC board is not properly installed.
C6902
DSC Bus check NG1-1
When DSC bus check detects an error.
C6903
DSC Bus check NG1-2
C6911
Undetectable
C6912
C6913
C6F01
Scanner sequence trouble 1
The original transport interval becomes shorter than the designed value due to an original transport control error in original reading in ADF.
C6F02
Reserved
C6F03
Reserved
C6F04
Reserved
C6F05
Reserved
C6F06
Reserved
C6F07
Reserved
C6F08
Reserved
C6F09
Reserved
C6F0A
Reserved
C6FDC
Reserved
C8101
Before reading pressure welding alienation mechanism
During a pressure motion being performed, the read roller sensor (PS6) output does not change from H to L.
During a retraction motion being performed, the read roller sensor (PS6) output does not change from L to H.
C8102
Turn around pressure welding alienation trouble
During a pressure motion being performed, the reverse roller sensor (PS7) output does not change from H to L.
During a retraction motion being performed, the reverse roller sensor (PS7) output does not change from L to H.
C8103
Lift up mechanism trouble (Upward movement)
The lift up upper sensor (PS16) is not turned ON after a lapse of a given time after the lift- up motor (M7) moves up (is turned forward).
C8105
Undetectable
C8106
Lift up mechanism failure
(Downward movement)
The lift up lower sensor (PS15) is not turned ON after a lapse of a given time after the lift- up motor (M7) goes down (is turned back- ward).
C8107
Glass cleaning mecha- nism trouble
The glass cleaning sensor (PS21) is not turned ON after the set period of time has elapsed after the glass cleaning motor (M9) is turned ON.
C8302
Cooling fan trouble
The lock signal continues to detect H during a given time while the cooling fan (FM1) is spinning
The lock signal continues to detect L during a given time while the cooling fan (FM1) is during halts.
C8401
EEPROM failure
EEPROM does not access normally
C9401
Exposure turning on the lamp trouble detection
The output from the CCD sensor is a prede- termined value or less during CCD sensor gain adjustment.
Scanner
C9402
Exposure turning on the lamp abnormally detection
The average output value of the CCD sensor with the scanner at its standby position is a predetermined value or more at the end of a scan job.
Scanner
CA051
Standard controller configuration failure
The controller of the MFP board (MFPB) is faulty.
CA052
Controller hardware error
A controller hardware error is detected in the network I/F.
CA053
Controller start failure
A controller start failure is detected in the controller interface.
CB001
FAX board error 1
See the FK-502 Service Manual.
CB002
FAX board error 2
CB003
FAX board error 3
CB051
FAX board mount failure line 1
CB052
FAX board mount failure line 2
CB110
FAX driver error: Instance generation error or observer registration error
CB111
FAX driver error: Configuration space ini- tialization NG
CB112
FAX driver error: Semaphore acquisition, release error
CB113
FAX driver error: Sequence error among main body tasks
CB114
FAX driver error: Message queue control error
CB115
FAX driver error: Main body - sequence error among FAX boards
CB116
FAX driver error: FAX board nonresponse (Nonresponse after initial- ization)
CB117
FAX driver error: ACK waiting timeout error
CB118
FAX driver error: Receiv- ing undefined frame
CB119
FAX driver error: DMA transfer error
CB120
JC soft error
CB122
Device error
(GA LOCAL SRAM)
CB123
Device error (DRAM)
CB125
Device error (GA)
CB126
Timeout error due to non- response from DC during suspension process
CB127
Timeout error due to non- response from CC during suspension process
CB128
Timeout error due to non- response from LINE dur- ing suspension process
CB129
Timeout error due to non- response from file system/ file driver during suspension process
CB130
MIF driver error: Driver soft error
CB131
MIF driver error: Reception frame length error from main
CB132
MIF driver error: Reception frame header error from main
CB133
MIF driver error: 232C i/f sequence error
CB134
MIF driver error: DPRAM i/f sequence error
CB135
MIF driver error: DPRAM CTL/STL register error
CB136
MIF driver error: AKC waiting timeout
CB137
MIF driver error: DPRAM RESET reception
CB140
MSG I/F Error with JC
CB141
I/F error with main: I/F error with driver
CB142
I/F error with main: Unde- fined command reception
CB143
I/F error with main: Com- mand frame length error
CB144
I/F error with main: Command parameter length error
CB145
I/F error with main: Undefined parameter
CB146
I/F error with main: Command/response sequence error
CB150
Line control: External class instance acquisition error
CB151
Line control: Job start error (Starting job parameter error/child job generation error)
CB152
Line control: Doc access error (Report buf access error)
CB153
Line control: Response wait timeout from external task
CB154
Line control: Internal que table control error (create/enque/deque)
CB160
1 destination control: Instance generation error
CB161
1 destination control: Timeout error
CB162
1 destination control: Interface error
CB163
1 destination control: Message que control error
CB164
1 destination control: Semaphore acquisition release error
CB165
1 destination control: Observer registration error
CB166
1 destination control: Reception resource check error
CB167
1 destination control: Deployment error of send- ing image information
CB168
1 destination control: Serialization error of receiving image
CB169
1 destination control: Access error to quick memory data
CB170
Page control: Internal que table control error (create/enque/deque)
CB171
Page control: Instance generation error
CB172
Page control: Timeout error
CB173
Page control: Interface error
CB174
Page control: Semaphore acquisition release error
CB175
Page control: Observer registration error
CB176
Page control: Unable to check TTI domain
CB177
Page control: Error return from TTI rasterizer
CB178
Page control: Receiving job generation error
CB185
Page control: Receiving data size logic error (Receiving data are not multiples of dotline)
CB186
Page control: Image buf acquisition (alloc) error
CB187
Page control: Error return from compressor
CB188
Page control: BandBuf control error (newInstance/get/free)
CC001
Vendor connection failure
It is detected that communications with the vendor are interrupted for a given period of time or more with “Installed” selected for the setting of vendor installation.
CC151
ROM contents error upon startup (MSC)
A fault is detected in a sequence of ROM contents check of the MSC (PRCB) during starting
CC152
ROM contents error upon startup (scanner)
A fault is detected in a sequence of ROM contents check of the IPB during starting.
CC153
ROM contents error upon startup (PRT)
A fault is detected in a sequence of ROM contents check of the mechanical control board (MFPB) during starting.
CC155
Finisher ROM error
Data of flash ROM of the finishing options is determined to be faulty when the power is turned ON.
CC156
ADF ROM error
Upgrade of the firmware has not been suc- cessful.
CC159
ROM contents error upon startup (DSC1)
A fault is detected in a sequence of ROM contents check of the DSC board during starting.
CC15A
ROM contents error upon startup (DSC2)
CC15B
Flash ROM error (saddle)
Data of flash ROM of the saddle is deter- mined to be faulty when the power is turned ON.
CC163
ROM contents error (PRT)
The wrong model of firmware is detected in the engine during the initial connection to the engine is being checked.
CC164
ROM contents error (MSC)
The wrong model of firmware is detected in the MFP board when the main power switch is turned ON.
CC165
ROM contents error (ADF)
When the power is turned ON, DF control board or firmware error is detected.
CC170
Dynamic link error during starting (AP0)
A dynamic link error occurs in the program on the MFP board due to an insufficient memory space available, a ROM fault, or other reason when the main power switch is turned ON.
CC171
Dynamic link error during starting (AP1)
CC172
Dynamic link error during starting (AP2)
CC173
Dynamic link error during starting (AP3)
CC174
Dynamic link error during starting (AP4)
CC180
Dynamic link error during starting (LDR)
CC181
Dynamic link error during starting (IBR)
CC182
Dynamic link error during starting (IID)
CC183
Dynamic link error during starting (IPF)
CC184
Dynamic link error during starting (IMY)
CC185
Dynamic link error during starting (SPF)
CC186
Dynamic link error during starting (OAP)
CC190
Outline font load error
An error occurred while loading the outline font.
CD002
JOB RAM save error
The error in save of job data to the memory/ hard disk and its read error are detected.
CD004
Hard disk access error (connection failure)
Unable to communicate between the hard disk and printer control board (PRCB).
CD00F
Hard disk data transfer error
Data transfer from the hard disk is faulty.
CD010
Hard disk unformat
Unformatted hard disk is connected.
CD011
Hard disk out of specifications mounted
A hard disk that falls outside the specifica- tions is connected.
CD020
Hard disk verify error
The data abnormality is detected by the HDD verify check.
CD030
Hard disk management information reading error
The machine fails to read administrative information data saved in the hard disk.
CD041
HDD command execution error
Address Mark Not Found
The error occurred inside the hard disk.
CD042
HDD command execution error
Address Mark Not Found
CD043
HDD command execution error
Address Mark Not Found
CD044
HDD command execution error
Address Mark Not Found
CD045
HDD command execution error
Address Mark Not Found
CD046
HDD command execution error
Address Mark Not Found
CD047
HDD SCSI library error
The error occurred inside the hard disk.
CD048
HDD SCSI library error
CD049
HDD SCSI library error
CD04A
HDD SCSI library error
CD04B
HDD SCSI library error
CD201
File memory mounting error
The file memory is not mounted.
The file has any abnormality.
CD202
Memory capacity discrepancy
File memory capacity on the MFP board (MFPB) is not enough.
File memory capacity necessary for duplex printing is not enough during duplex unit mounting.
CD203
Memory capacity discrepancy 2
File memory capacity on the MFP board (MFPB) is not enough.
CD211
PCI-SDRAM DMA
operation failure
Hardware related to the transfer of memory image of the MFP board (MFPB) fails to respond.
CD212
Compression/extraction timeout detection
Hardware related to the BTC compression function of the MFP board (MFPB) fails to respond.
CD231
No FAX memory at FAX board mounting
The DIMM for FAX is not mounted during the FAX board is mounting.
The FAX board is not mounted when the FAX board mounting is set ON at Service Mode.
CD241
Encryption ASIC error
Initialization error of the encrypted ASIC is detected during the machine is starting.
CD242
Encryption ASIC mounting error
The faulty of the installation of encrypted ASIC is detected during the machine is starting.
CD251
Undetectable
CD252
No relay circuit boards for IC-412 mounting at
IC-412 mount setting
Relay circuit boards (VI-505) are not mounted when the IC-412 is set to mount setting at Service Mode.
CD261
USB host board failure
When a failure is detected in USB host board included in the local interface kit.
Non-standard USB device is connected.
CD271
i-Option activated and additional memory not installed
While the i-Option is activated, the addi- tional memory included in UK-203 is not installed.
CD272
i-Option activated and additional memory and HDD not installed
While the i-Option is activated, the addi- tional memory included in UK-203 and the HDD are not installed.
CD3##
NVRAM data error
Abnormality is detected by the abnormal check of each NVRAM data.
CD370
NVRAM data multiple errors
Multiple errors (Over 5) are detected by the abnormal check of each NVRAM data.
CD401
NACK command incorrect
When abnormality is found in the communi- cation of controller.
CD402
ACK command incorrect
CD403
Checksum error
CD404
Receiving packet incorrect
CD405
Receiving packet analysis error
CD406
ACK receiving timeout
CD407
Retransmission timeout
CDC##
Trouble related to security
Contact the responsible people of KMBT before taking some countermeasures.
CE001
Abnormal message queue
MFP board (MFPB) is faulty.
CE002
Message and method parameter failure
CE003
Task error
CE004
Event error
CE005
Memory access error
CE006
Header access error
CE007
DIMM initialize error
CEEE1
MFP board malfunction
MFP board (MFPB) is faulty.
CEEE2
Scanner section malfunction
A scanner part is faulty.
CEEE3
Printer control board malfunction
Printer control board (PRCB) is faulty.

If you’re not able to find the solution?